The range · start here

Find your suite.

Every Facada opening starts with a suite — the steel profile system it’s built from. It sets the sightline, the glazing, the thermal performance and the price. Compare them, see how steel stacks up against the alternatives, then answer a few questions and we’ll point you to the right one.

Entry · standardised SF20

The most accessible way into steel — standardised sizes, single-glazed.

Internal & heritage W20

The slimmest sightlines for internal screens and heritage work.

Standard external W40

The everyday double-glazed suite for most new-build openings.

Thermally broken W50 TB · M65 TB · W75 TB

For cold climates — a thermal break stops the cold path. Deeper = warmer, bigger glass.

Strength & security FPS50

Uninsulated, maximum-strength steel — large, commercial, fire & security-rated openings.

Bespoke Custom

Anything the standard set doesn’t cover, built the same way.

The range · 8 suites · 29 standard styles

A suite for every
opening.

Pick a style, then the suite that carries it: SF20 for the accessible way in, W20 for the slimmest sightlines, W40 for everyday double-glazed work, the thermally broken W50 TB / M65 TB / W75 TB for cold or coastal sites, FPS50 for the strongest openings, and Custom when the standard set doesn’t fit. Every opening is made to your dimensions.

cross-section Approx. 20mm face
Entry · standardised
SF20
The standardised series. The accessible way into steel.
Glazing
Single 6mm, or slim 20mm IGU
Depth
Approx. 20mm face
Thermal
Single-glazed
Best for
Internal screens & sheltered openings, standard sizes
Build with SF20
cross-section Approx. 22mm sightline
Internal & heritage
W20
The slimmest. Single-glazed.
Glazing
Single, or double up to 20mm IGU
Depth
Approx. 22mm sightline
Thermal
1.2 W/m²K (20mm IGU)
Best for
Heritage, internal partitions, mild climates
Build with W20
cross-section 42–47mm
Standard external
W40
The everyday. Double-glazed.
Glazing
Double, up to 27mm IGU
Depth
42–47mm
Thermal
1.0 W/m²K (27mm IGU)
Best for
Residential, most external openings
Build with W40
cross-section Approx. 50mm
Thermally broken
W50 TB
Thermally broken. 50mm.
Glazing
Double or triple, up to 37mm IGU
Depth
Approx. 50mm
Thermal
1.0 W/m²K (37mm IGU)
Best for
High-performance, alpine, coastal
Build with W50 TB
cross-section Approx. 65mm
Thermally broken
M65 TB
Thermally broken. 65mm. Bigger glass.
Glazing
Double or triple, up to ~50mm IGU
Depth
Approx. 65mm
Thermal
Uf from >1.0 W/m²K
Best for
Higher thermal performance, larger spans, cold climates
Build with M65 TB
cross-section 75mm construction depth
Thermally broken
W75 TB
Maximum thermal. 75mm. Triple-glazed.
Glazing
Triple, 26–56mm (units to 52mm)
Depth
75mm construction depth
Thermal
Uf from >1.0 W/m²K
Best for
Passive house, alpine, the coldest climates
Build with W75 TB
cross-section 50mm structural (uninsulated)
Strength · security
FPS50Forster Presto 50
Uninsulated. Strongest. Security & fire.
Glazing
Single / laminated
Depth
50mm structural (uninsulated)
Thermal
Uninsulated
Best for
Large, high-traffic & commercial openings; fire, smoke & anti-burglar options
Build with FPS50
Suite SF20W20W40W50 TBM65 TBW75 TBFPS50
Relative cost
Best for Entry · standardisedInternal & heritageStandard externalThermally brokenThermally brokenThermally brokenStrength · security
Glazing Single 6mm, or slim 20mm IGUSingle, or double up to 20mm IGUDouble, up to 27mm IGUDouble or triple, up to 37mm IGUDouble or triple, up to ~50mm IGUTriple, 26–56mm (units to 52mm)Single / laminated
Construction depth Approx. 20mm faceApprox. 22mm sightline42–47mmApprox. 50mmApprox. 65mm75mm construction depth50mm structural (uninsulated)
Sightline Approx. 20mm faceApprox. 22mm faceStepped-leg, reads near-W20Matched to W40Slim, matched family27mm frame / 49mm leaf-frameNarrow face
Max glazing Single or slim 20mm IGUUp to 20mm double glazed unitUp to 27mm double glazed unit (insulating glass up to 30mm)Double or triple glazing up to 37mmDouble or triple glazing up to ~50mmTriple glazing up to 52mmSingle or laminated safety glass
Thermal break High-density cast-in polyurethane isolatorGlass-fibre reinforced polyamide isolatorGlass-fibre reinforced polyamide isolator
Thermal (U-value) Single-glazed1.2 W/m²K (20mm IGU)1.0 W/m²K (27mm IGU)1.0 W/m²K (37mm IGU)Uf from >1.0 W/m²KUf from >1.0 W/m²KUninsulated
Wind resistance Sheltered / internalUp to Class C5 — 2000 PaUp to Class C5 — 2000 PaClass C3 (1200 Pa) inward; up to Class C5 (2000 Pa) outwardUp to Class C5 — 2000 PaUp to Class C5 — 2000 PaHigh / structural
Watertightness Class 7B inward; up to Class 9A (600 Pa) outwardUp to Class 9A — 600 PaUp to Class 9A — 600 Pa
Acoustic Up to 43 dBUp to 44 dBUp to 44 dB (-2;-5)
Internal / external InternalInternalExternalExternal (cold)External (cold)External (cold)Internal

Indicative figures from the system catalogues — final performance is confirmed per opening on shop drawings. M65 TB and FPS50 figures to be verified.

Facada steelAluminiumTimberTraditional steel
Sightlines Slimmest — 20–25mmBulky — 50–90mmHeavy — 90mm+Slim, but single-glazed
Strength HighestLow — flexesModerateHighest
Thermal Thermally broken optionsBroken, but bulkyNaturally warmPoor — no break
Durability Decades, recoatable15–25 yrsNeeds upkeepDecades, rust risk
Maintenance Low — wipe & inspectLowHigh — reseal/repaintHigher — rust care
Look Crisp, structuralCommercialSoft, warmHeritage
Relative cost PremiumLowestMidPremium

Tell us about the opening.
We’ll name the suite.

1 · Where does it go?
2 · Glazing?
3 · How big?
4 · What kind of project?
Your recommendation

Answer the questions and we’ll point you to the right suite — then you choose the door type and style.